Our site uses cookies necessary for its proper functioning. To improve your experience, other cookies may be used: you can choose to disable them. This can be changed at any time via the Cookies link at the bottom of the page.


High Temperatures on PE Pipes for Water Supply Pressure Verification [PE]

 

Plastic Pipes Conference Association # 2012 Barcelona

Chen Zenggui

For PE pipes for water supply installed in the summer, the pipeline’s temperature under the sun exposure can influence the properties of the pipe. If you carry out the pressure tests directly, it can result in damage to the pipeline. So we conducted a detailed analysis and research on the influence of exposure to the sun on pipe properties. We also considered the effect of surface scratches that can be caused during transportation and handling on the pressure resistance of the pipe. The results show that the high temperature is an important factor about effecting on the PE pipes for water supply’s pressure capacity. Therefore when the pressure test is carried it we must follow the procedures of the national construction specification “Buried polyethylene water pipeline engineering technical regulations” for installation and acceptance, to ensure that quality polyethylene water supply pipe and project acceptance will be successfully passed. Keywords : PE pipe, high temperature, Hydraulic pressure, Hydraulic pump

Please note that the whole article content is available on PPCA website only :

Related papers

2018 Las-Vegas : Preparation and studying of two-layer oxygen barrier plastic pipe

Author(s) : Mingyuan Hu, Dongming Yu, Zhangcheng Chen, Cheng Zhi, Kaige Duan

Studying in barrier property of TLCP/PO alloy and EVOH/PO alloy. Filtrating formulas with extruding alloy into pipes. Trying to coat alloy on pipes and co-extrude into two-layer oxygen barrier plastic pipe. The traditional Ethylene vinyl alcohol copolymer (EVOH) barrier plastic pipe used in internal closed-loop...

2016 Berlin : A novel cyclone single stack system for building drainage

Author(s) : Chen Jianchun, Liu Luliang

3S (Strengthen Single System) cyclone single stack system is a new product for building drainage, which has the advantages of saving materials, large drainage quantity, low drainage noise, etc. In this system, the guide structure, swirl angle, volume structureand the height of spiral reinforcement are optimized...

2014 Chicago : Influence of Additives on Structure and Property of Bimodal Polyethylene Pipe Material YGH041T

Author(s) : Qu Yunchun, Sun Xuhui, Chen Guokang

The polyethylene resin whose relative molecular mass distribution shows bimodal (Bimodal PE) possesses not only favorable mechanical property, but also excellent processing property. Currently, Borstar Technology of Borealis Company—loop slurry reactor and gas fluidized bed reactor install in series, which is...

2014 Chicago : Liquid Crystal Polymer in the Manufacture of Plastic Pipes

Author(s) : Dongming yu, Linan Chen

This article is the impact study on general plastic pipe performance when using Liquid Crystal Polymer (hereinafter LCP) and LCP alloy, the soaking extrusion in-situ composite technique and the coat-molding technique for plastic pipe extrusion. It turns out that the high barrier property of TLCP can help us...

2012 Barcelona : The evolution and application of large diameter steel reinforced plastic pipes for sewerage engineering in China

Author(s) : Chen Que, Xu Shengguang, Su Min

This paper will discuss the application of some kinds of steel reinforced plastic pipes for sewerage engineering in China, and give some proposals for the development of the product. Keywords : The large diameter; steel reinforced plastic pipes; pipes for sewerage engineering; application

2006 Washington DC : Establishing the Correlation Between S4 & Full Scale Rapid Crack Propagation

Author(s) : Mason, Chen

The small scale steady state (S4) test is a convenient and relatively inexpensive means of measuring the critical pressure (Pc) for rapid crack propagation in plastic pipes. The critical pressure measured in the S4 test is not the same as the critical pressure measured in a full scale test, which more directly...

2004 Milan : Technical Review of Rilsan Polyamide-11 High Pressure Natural Gas Pipe Field Installations, Coiling Studies, and Pipe Durability Testing

Author(s) : James Mason, John Chen and Gregory O’Brien

This paper presents an overview of the first high pressure polyamide-11 (PA-11) natural gas plastic pipe field installations with operating pressures of 150 to 200 psi. We describe the layout and operating pressures, the local soil and environment conditions, as well as the installation methods employed to complete...

2001 Munich : Ductile Failure and Delayed Necking in PE

Author(s) : Jivraj, Sehanobish, Dun, Damen, Wu, Zhou, Chen, Shulkin, Chudnovsky

Analysis of polyethylene (PE) pipes ductile failure (ballooning) suggests that it is directly related to the delayed necking phenomena and time to ductile failure of PE pipe can be evaluated as the time to delayed necking. The necking in polyethylene (PE) is studied under displacement control (ramp test) and load...

Recent Advances in Larger Diameter Polyamide-11 Gas Distributuin Piping Systems

Author(s) : Mason, Chen, Dang

Members of the Association

BOREALISBOROUGEFormosa Plastics CorporationHanwha TotalEnergiesINEOS O&PIRPCKorea Petrochemical IND. Co., LTD (KPIC)LyondellBasellPetroChina Dushanzi Petrochemical CompanyPRIME POLYMERSABICSCG Chemicals & Thai PolyethyleneSinopecTASNEE
TOP