Our site uses cookies necessary for its proper functioning. To improve your experience, other cookies may be used: you can choose to disable them. This can be changed at any time via the Cookies link at the bottom of the page.


PE technical guidance
HDPE Pipe technical guidance (High quality Polyethylene Pipes)
 

End fittings

Quick access

Trenchless installation and rehabilitation techniques that use standard PE100 pipes also use standard end fittings to connect to other pipe materials. These may be fused or mechanical fittings depending on the needs and design of the pipeline in question. These are designed and installed in the same way as when used in open trench working but care must be taken to ensure that they provide adequate end load capability and shear support. Fittings for connecting PE100 pipe to other pipe materials or to appurtenances such as valves and hydrants must have internal support to the pipe in the form of inserts.

Standard fittings are used with:

  • Directional drilling
  • Pilot tube microtunnelling
  • Pipe bursting and splitting
  • Sliplining
  • Mole ploughing
  • Impact moling
  • Pipe reaming
  • Pipe extraction

For the techniques that use or result in non-standard dimensions, specifically the close-fit technologies in which the dimensions are changed during the process and may not revert to a standard diameter, expanded PE fittings or special mechanical fittings are necessary for connection to other pipework.

The examples given here refer to three mechanical fittings commonly used in the UK: Transgrip, Aquagrip and Linergrip. These are used to illustrate the principles and similar fittings are in use in the UK and internationally. The Multi/Joint fittings from GF Waga are similar and a link is provided below.

Transgrip fittings were developed specially for Die Drawing, where the liner end expands to a larger diameter than the host pipe, and they are designed so that the insert does not extend into the host pipe. As a result, they are able to cope satisfactorily with a range of host pipe IDs.

Linergrip fittings are designed so that the insert sits partially inside the host pipe, so they can only be used successfully when the host pipe ID is known exactly. Linergrip fittings cannot be used for Die Drawing.Where the host pipe ID varies, this may make the installation of Linergrip fittings difficult or even impossible because these have to be ordered in advance, and for this reason it may be more appropriate to select Transgrip fittings, which can be accommodate such variations of host pipe ID.

Aquagrip fittings are designed for fully structural liners, such as used in slip lining, but for ‘best practice’ means should be provided to seal the annular gap at the host pipe ends, to prevent ingress of ground or backfill material, and prevent groundwater circulation which would allow internal corrosion of the host pipe to continue

All fittings should be carefully aligned with the host pipe, and under no circumstances should a fitting be canted in an attempt to align the flanges ready for piecing up. Once the ends have been terminated, they can be blanked off and the main filled and pressurised to the pressure and for the time stated in the installation manual. Whilst under pressure, the terminations should be visually examined for any signs of leakage, after which the main can be drained down and the blanks removed, ready for final inspection.

End fittings

End fittings


PE Cat fitting. (from WASK-UK website)

TRANSGRIP

Image Courtesy: Exova Utilities

This diagram shows the Transgrip fitting, which is specifically designed to terminate die drawn liner pipes, providing full end load capability and shear support. Such a fitting MUST be used to terminate Die Drawn lining works and should be used for Rolldown where there is any doubt about the host pipe ID. It is also advisable in folded close-fit lining when there is doubt about the host pipe ID.

The Transgrip fitting also provides a degree of sealing around the host pipe against ingress of ground water, but the effectiveness of this depends largely upon the surface condition and cleanliness of the host pipe end. It does not and cannot provide any angular restraint. Therefore during installation the flange of the ‘piecing up’ pipe must be aligned to the liner termination flange, and not vice versa.

Although there is a short length of liner unsupported in a Transgrip installation, the length is so short as to be well within the gap spanning capability of the PE liner pipe.

AQUAGRIP

Aquagrip is a fully structural liner fitting which is terminated outside the host pipe and is therefore suitable for use with liners that are fully structural.

Body of the Aquagrip insert being inserted.

Body of the Aquagrip insert being inserted.

Image courtesy : Exova Utilities

Fitting In Place
Fitting In Place

Image courtesy : Exova Utilities

LINERGRIP

With the exception of Die Drawing, provided that the host pipe ID is accurately known, a Linergrip can be used, and for this the liner is cut off close to the end of the host pipe, and the hydraulic expander/air bag is applied, As the expansion is carried out partially inside the host pipe, great care must be taken so as not to over-expand the liner and crack the host pipe. It is usually helpful to use a jack to hold the liner pipe fully open while the Linergrip insert is applied. This is a difficult operation, and speed is of the essence once the expander has been withdrawn.

End fittings

Image courtesy : Exova Utilities

This diagram shows the Linergrip and it can be seen that the ID of the host pipe is critical, as the insert sits inside the liner pipe which in turn sits inside the host pipe. Thus, if the ID of the host pipe is too small, the insert will not fit. The green ring is the ‘necklace’ of gripper pads that make the fitting fully end load capable.

End fittings

Image courtesy : Exova Utilities

This picture shows the insert (black Rilsan coated) after insertion, with the jack still in position. Once the insert is in place, and the surface of the liner pipe end has been carefully inspected for any damage such as scoring, particularly in the area where the seal will sit, and any such damage has been carefully scraped out, the fitting can be assembled in accordance with the fitting manufacturer’s instructions.

These fittings are not designed to accommodate angular displacement, and must therefore be fitted in line with the host pipe, and under no circumstances may they be ‘kicked’ to better align them with the incoming make up piece.

When installing gaskets or sealing rings it is important that the components containing the seats for these gaskets or rings are supported so that the seats are concentric. This is particularly important on large and therefore heavy fittings, and ensures that all the bolt tension is available for compressing the gasket or ring, and is not dissipated trying to pull the components into alignment.

Fitting In Place

Fitting in place

Image courtesy : Exova Utilities

Ultra grip fitting is also available up to DN600

Ultra grip fitting is also available up to DN600. Refer to Viking Johnson website.

Image Courtesy : Viking Johnson

USEFUL LINKS

Last update Wednesday 01 July 2015
Slip lining

SLIPLINING - TECHNIQUE Slip-lining is perhaps the oldest of all trenchless techniques. It involves the insertion of a new PE100 liner pipe of standard diameter and SDR into an existing pipe. Under...


Members of the Association

BOREALISBOROUGEFormosa Plastics CorporationHanwha TotalEnergiesINEOS O&PIRPCKorea Petrochemical IND. Co., LTD (KPIC)LyondellBasellPetroChina Dushanzi Petrochemical CompanyPRIME POLYMERSABICSCG Chemicals & Thai PolyethyleneSinopecTASNEE